STANDARDS AND REPORTS on DÜKAP™ FLOORING

 
Certificate on "Standards Suitability"
DÜKAP™ rubber flooring product quality is certified and guarantied by Turkish Standards Institution (TSE) and DÜKAP™ flooring fully comply with Turkish Standards Institution's "Solid Rubber Flooring" standard number: "TSE TS 4857", date: November 1986. The authorisation to use the "TSE" guaranty and place the "TSE" label on DÜKAP™ rubber flooring was granted by Turkish Standards Institution * on January 28th 1988.

Certificate on "Production Qualification"
Following official inspection and evaluation of our management and manufacturing plant facilities, "Production Qualification Certificate" was awarded to our company by Turkish Standards Institution. Article number:132, dated January 28th 1988 under document number 14.01/1722.

Certificate on DÜKAP™ "AS" Anti-Static Flooring
Following inspection and testing by "TÜBITAK" ** Marmara Research Institute, DÜKAP™ "AS" tiles were recognised and certified for their "Anti-Static Characteristic" on December 22nd 1987.

Certificate on DÜKAP™ "AG" Flame Retardant Flooring
Following inspection and testing by "TÜBITAK" Marmara Research Center, DÜKAP™ "AG" tiles were recognised and certified as "Flame Retardant". Their report issued on February 8th 1993, number "93-181 B.02.BAK.5.01.42.00/103-00683 confirm DÜKAP™ "AG" tiles as "Fire Retardant" and that they fully comply with the "DIN 51960" Standard.


* "Turkish Standards Institution" is the sole official authority, obligated by law, to prepare, regulate and enforce Standards in Turkey.

** "TÜBITAK" Marmara Research Institute and Center, is an official governmental organisation obligated by law to promote and help scientific research and development in Turkey.


TECHNICAL SPECIFICATIONS


CHARACTERISTICS * STANDARD REQUIRED UNIT DÜKAP ST
KD
DÜKAP ST/SL KD/SL DÜKAP DZ DZ/DS DÜKAP HD Studded DÜKAP HD Smooth
TOTAL THICKNESS TS 4857
DIN 16852
3,4,5,6 ± 0.3 4 mm mm 4.0 3.3 4.0 6.0 6.0
TILE SIZE TS 4857 % ± 0.15 500x500 mm 500x500 500x500 500x500 442x442 442x442
TOTAL WEIGHT       gr/m2 ST 5400
KD 5800
5060 6350 8400 9450
ABRASION (5 N load)
DIN 53516
TS 547
< 150 mm3 135 135 135 135 135
HARDNESS TS 1324
DIN 53505
80-86 ± 4
87-96 ± 3
> 70
Shore A 88 88 88 88 88
INDENTATION TEST (1) TS 4857
DIN 51955
< % 10
< 0.35
%
mm
% 4
< 0.35
% 4
< 0.35
% 4
< 0.35
% 4
< 0.35
% 4
< 0.35
BENDING RESISTANCE DIN 53509   mm
radius
> 60 > 60 > 60 > 60 > 60
ACOUSTIC INSULATION (2) DIN 52210 > 12 dB > 12 > 12 > 12 > 12 > 12
RESISTANCE TO CHEMICALS TS 4857
DIN 51958
no discoloration   qualify qualify qualify qualify qualify
RUBBER CONTENT TS 5002 > % 35
by volume
% > 50   > 50 > 50 > 50 > 50
DIMENSIONAL STABILITY (3) DIN 51962 < 0.6 mm < 0.6 < 0.6 < 0.6 < 0.6 < 0.6
CORNER ACCURACY OF TILE (4) TS 4857   < % ± 0.1
tolerance
% < ± 0.05 < ± 0.05 < ± 0.05 < ± 0.05 < ± 0.05
COLOUR RESISTANCE TS 4857
DIN 53389
    qualify qualify qualify qualify qualify
CIGARETTE BURN RESISTANCE DIN 51961     no burn no burn no burn no burn no burn
FIRE BEHAVIOUR DIN 4102
DIN 51960
B2 (5)   B1 B1 B1 B1 B1
ELECTRICAL INSULATION DIN 53596 > 107
AS(6) 104-108
Ohm > 107
AS < 105
> 107
AS < 105
> 107
AS < 105
> 107
AS < 105
> 107
AS < 105

* Tests conducted according to relevant TSE and DIN norms. Results, TSE and/or Quality Control lab. Delsa. Colour tone variations due to different production dates and batches or technical modifications to improve the product must be accepted.


(1)Deepness of the permanent impression.
(2)Betterment of footfall sound absorption.
(3)Alteration of dimensions due to heat influence.
(4)Accuracy of the tile edge length at 23 °C.
(5)According to DIN 4102, part 1.
(6) Antistatic quality flooring
.



Home Page | Applications | Characteristics | Products | References | Prices and Freight | Installation and Care | Standards and Reports | Additional Rubber Products | Product Colour Palette | Product Patterns